Зареждане...
Surface area and pore size analyzers: Nova X00
Surface area and pore size analyzers: Nova X00 Surface area and pore size analyzers: Nova X00

Surface area and pore size analyzers: Nova X00

АДСОРБЦИОННИ АНАЛИЗАТОРИ

 

  • Maximize your budget with this multi-station BET surface area analyzer 
  • Boost throughput with two analysis, four degassing stations
  • Conserve helium using short sample cells and NOVA mode
  • Achieve 2 % reproducibility with ≥2 m2 measurement surface area
  • Simplify the analysis process with built-in profiles
  •  
  •  

  •  
Запитване
Тагове:
АДСОРБЦИОННИ АНАЛИЗАТОРИ \ ОБРАЗОВАНИЕ/НАУКА - Институти, университети \ ФАРМАЦИЯ – Лекарствени препарати
Integrated sample preparation simplifies your process
Eliminate the clutter, cost, and complexity of external degassing devices with four integrated degassing stations and up to four analysis stations in one space-saving design. Prepare a range of samples with vacuum or flow degassing at temperatures up to 425 ºC. Degassing is software programable and linked with an individual sample ID, ensuring full traceability. 

Speed up your surface area and pore size analysis with NOVA Mode
Utilize pre-calibrated sample cells – no need to measuring void volumes before every analysis – and accelerate your analysis speeds while maintaining a high level of measurement precision.

TruZone – active coolant level control
With TruZone, create and maintain a small cold zone on the sample cell and maximize the measurement sensitivity of your surface area and pore size analyzer. Increased sensitivity when measuring gas molecules that are adsorbed by the sample results in exceptional measurement performance. Nova instruments deliver better than 2 % reproducibility with as low as 2 m2 total surface area in the sample cell. This best-in-class performance lets you measure materials with specific surface areas as low as 0.01m2/g.

Suite of smart dosing algorithms for effortless method creation
Intelligent dosing algorithms, such as DoseWizard, VectorDose, and Initial Fill, simplify the creation of analysis profiles to accelerate analyses without sacrificing precision. In combination with the 20+ built-in analysis profiles for standardized methods like ASTM, ISO, USP, and DIN, our surface area and pore size analyzer delivers operational simplicity from start to finish.

A surface area and pore size analyzer with smart software
Combine instrument control and data processing with Kaomi for Nova. Set up and perform analyses, and process, report, and store data easily. Control up to four Nova instruments from one PC.

21 CFR Part 11-compliant software
Enhance data integrity for the pharmaceutical industry with Kaomi for Nova 21 CFR Part 11 Software (user management, audit trail, customizable reporting, and electronic signature). Comply with the FDA’s 21 CFR Part 11 guidelines with our comprehensive pharma qualification and requalification package.

Technical specifications

  Nova 600 BET Nova 800 BET Nova 600 Nova 800
Analysis specifications
Measurement principle Vacuum Volumetric
Analysis gases Nonly N2, Ar, CO2, and other non-corrosive gases
Analysis stations 2 4 2 4
Independent P0 station Yes
Relative pressure range (P/P0 ) 10-4 to 0.5 10-4 to 0.999
Pressure measurement accuracy 0.1 % (of full scale) *
Pressure resolution Absolute : 1.2 x 10-4
Torr Relative : 1.5 x 10-7 p/p0
Lower specific surface area limit From 0.01 m2/g
Lower absolute surface area limit From 0.5 m2
Surface area reproducibility  2 %**
Pore size range N/A 0.35 - 500 nm (Diameter) (0.35 - 1.1 nm only with CO2)
Minimum pore value N/A 1.2x10-8 cm3
Truzone Yes
Powerprotect Yes
Dosewizard Yes
Vectordose Yes
Analysis dewar Volume: 1 L
Duration: Up to 7 Hours
Volume: 2 L
Duration: Up to 40 Hours
Sample preparation Integrated Degassing Stations : 4
Temperature Control: 2 Heating Zones, Ambient to 425 oC
Available Methods: Flow & Vacuum, Programable Multi-Step Heating Profiles
Physical specifications
Dimensions (DxWxH) 44 cm x 63 cm x 84 cm
Weight 63 kg
Operating environment Temperature : 15 to 35 oC
Humidity : 20 to 80 % relative, non-condensing
Wetted parts Stainless steel, Viton elastomers
Gas Ports: 5 (3 Analysis, 1 Helium, 1 Degas/Backfill)
Purity: 99.999 % (He, N2)
Input Pressure: 8 to 10 PSIG
Vacuum connection Rotary Pump Exhaust Port, KF 16
Vacuum requirements Ultimate vacuum of 2.3 x 10-3 Torr
Electrical Supply : AC 100~240 V AC , 50 / 60 Hz Consumption: 345 VA (Maximum)
Additional specifications
Display 10-inch Touchscreen
PC connection  Ethernet
Kaomi for Nova Software Instrument Control: Up to 4 Instruments 
6 Languages: English, French, German, Japanese, Chinese, Spanish
Kaomi for Nova 21 CFR Part 11 Software Features: User management, audit trail, customizable reporting, and electronic signature to enhance data integrity for use in the pharmaceutical industry
Pharma Qualification Package Yes
Pre-loaded analysis profiles 20+ (ASTM, USP, DIN, ISO)
ROHS 3 compliant Yes
CE certified Yes

* Includes precision, linearity, and hysteresis s of the complete pressure measurement system
** Performed with BAM P115 certified reference material